Language
CN
EN
Solutions
Industries
Enterprise Network
- 5G Branch Office
- 5G Private Network
- 5G WiFi Coverage in Construction Site
- 5G Smart Factory
Logistics and Retail
- Smart Parcel Locker
- Smart Vending Solution
- Digital Signage Solution
- Gaming & Lottery
Industrial Automation
- Industrial Robot
- Injection Molding Machine
- CNC/PLC
- Air Compressor Monitoring System
- Automatic Guided Vehicle
- VPN Based Remote Monitoring
Energy Management
- Intelligent Transformer Substation
- Smart Meter Installation Signal Analyze
- Power Distribution
- Solar Energy Remote Monitoring
- Automatic Meter Reading
- Intelligent Operation and Maintenance of Power Distribution Room
- Oil & Gas Pipeline Monitoring
Transportation
- Transit Bus Solution
- Highway Tunnel Surveillance and Controller
- Video Upload In The Bus Station
- Railway Networking Solution
- Public Wi-Fi
Healthcare
- Smart Mobile Nursing Trolley
- 5G Telemedicine
- Networking Solution of Ambulance
- Management Solution of Medical Machines
Smart City
- Self-service Check Out Machines
- PoE Wireless Monitoring
- HVAC Network Solution
- EV Charging Pile
- Elevator Monitoring
Environment
- Smart Water Management System
- Urban Flood Monitoring
Finance
- Bank ATM Networking
Agriculture
- 5G Intelligent Agriculture
Technologies
5G Edge AI and Cloud
Link Backup
SD-LAN
Client Cases
Automated Parcel Locker Project
Bank ATM Machine Monitoring
ALL CASES
Industries
Enterprise Network
Logistics and Retail
Industrial Automation
Energy Management
Transportation
Healthcare
Smart City
Environment
Finance
Agriculture
5G Branch Office
5G Private Network
5G WiFi Coverage in Construction Site
5G Smart Factory
Smart Parcel Locker
Smart Vending Solution
Digital Signage Solution
Gaming & Lottery
Industrial Robot
Injection Molding Machine
CNC/PLC
Air Compressor Monitoring System
Automatic Guided Vehicle
VPN Based Remote Monitoring
Intelligent Transformer Substation
Smart Meter Installation Signal Analyze
Power Distribution
Solar Energy Remote Monitoring
Automatic Meter Reading
Intelligent Operation and Maintenance of Power Distribution Room
Oil & Gas Pipeline Monitoring
Transit Bus Solution
Highway Tunnel Surveillance and Controller
Video Upload In The Bus Station
Railway Networking Solution
Public Wi-Fi
Smart Mobile Nursing Trolley
5G Telemedicine
Networking Solution of Ambulance
Management Solution of Medical Machines
Self-service Check Out Machines
PoE Wireless Monitoring
HVAC Network Solution
EV Charging Pile
Elevator Monitoring
Smart Water Management System
Urban Flood Monitoring
Bank ATM Networking
5G Intelligent Agriculture
Technologies
5G Edge AI and Cloud
Link Backup
SD-LAN
Use Cases
Automated Parcel Locker Project
ALL CASES
Products
IoT Routers
H8951 4G Cellular VPN Router
H8952 RedCap IoT Router
H8922S 4G Dual SIM VPN Router
H8923 5G Wi-Fi Router
Edge Routers
H8959 4G Cellular VPN Router
H8860 5G Enhanced Wi-Fi Router
IIoT Gateways
X1 4G Industrial Gateway
Z1 5G Industrial Outdoor Gateway
Z2 5G Industrial Gateway
Z4 Edge Computing Gateway
Edge AI Gateways
Smart 2000 5G Edge AI Box
Smart 3000 5G Edge AI Box
In-Vehicle Series
H7960 4G POE+ Router
H3960 Vehicle Gateway
H3318C MDVR Gateway
H3380 Dual-mode 5G Vehicle-mounted Integrated Gateway
Consumer Routers
A500Q AX5400 5G CPE
A500M AX3600 5G CPE
Cloud Service
Wedora Device Manager
Platform Function
Platform Advantage
Successful Cases
Version Classification
Project Demo Tryout
Support
Return Policy
RMA Service
Download Center
Document Library
Product Support
Security Center
FAQs
Resources
News
Blog
Events
Whitepaper
Newsletter
About Us
Company
Overseas Team
Contact
Support and Services
Home
Support
Cellular Router
Return Policy
Download Center
Product Support
FREQUENTLY
ASKED QUESTIONS
Cellular Router
Edge-computing Gateway
Android Industrial Computer
Q: The LAN1-4 of H8922S is configured with different network segments. Can communication between these four network segments be possible?
A: Yes. The IP of the lower computer and the configuration of the gateway must correspond. For example, if the LAN1 IP is 192.168.9.x, you need to configure the gateway to 192.168.9.1. It cannot be configured to 192.168.8.1.
Q: Does Hongdian router support custom LAN port communication rate?
A: Yes, both LAN and WAN ports support configuration rate and duplex mode.
Q: Does H8922S support loadbalance?
A: Yes, H8922S supports dual-mode and policy routing based on MAC address. The number of MAC addresses on each link is evenly allocated to realize dynamic load balance. Another way of Loadbalance is that it can support the static specification of policy route to realize the traffic load balance.
Q: How to set the remote log of the router?
A: Need a Log server with remotely reachable IP to run the Syslog tool, fill in the Server ip/port in System-->Remote Log, and you can view the log of the device in the Log server.
Q: How long can the router's Local log view the recent running log?
A: For H89xx routers, the default storage is 80KB, and CLI modification is supported. Local log can save up to 1M in size. When the log capacity exceeds 10M, the previous log will be automatically overwritten.
Q: After the router restarts, can I check the previous log?
A: The device log is stored in RAM. After device is restarted, the log is cleared. To capture logs, you can use remote log feature.All logs can be sent to the remote server synchronously.
Q: How to modify the login address of the routing setting page (192.168.8.1)?
A: Log in to the router configuration interface, enter the Network→LAN page, modify the IP address of IP1 to a new IP address, and then click the save button to use the new IP address for access.
Q: How to modify the wireless router login management password?
A: Log in to the router configuration interface, enter the System→Account page, click the Mod button next to the user to be modified, enter the old password and the new password.
Q: What should I do if I forget the management password of Hongdian router?
A: The router password can be reset by restoring the factory settings. The default user name and password are restored to admin and admin.
Q: What is the default port number of the router for web access and can it be modified?
A: The default web port is 80, and the web port number can be modified through System->Account.
1
2
3
4
5
···
If you have other questions,
please contact us!
*
First Name
*
Last Name
*
Email
*
Phone
*
How can we help you
submit
Looking For
IoT Products And Solutions?
We promise you the best customer service so contact a Hongdian expert and get started today!
Contact Us
Subscribe to us
SUBMIT
Products
IoT Routers
Edge Routers
IIoT Gateways
Edge AI Gateways
In-Vehicle Series
Consumer Routers
Solutions
Enterprise Network
Logistics and Retail
Industrial Automation
Energy Management
Transportation
Healthcare
Smart City
Environment
Finance
Agriculture
About Us
Overseas Team
Contact
Tower A, Hongdian Building, 100 Huabao Road, Pinghu, Longgang District, Shenzhen, 518111, China.
Tel: +86-755-88864288-2
Email: sales@hongdian.com
Privacy Policy
|
Terms of Service
Copyright © 1997-2024 Hongdian. All rights reserved.
Support
whatsapp:
+86-18025415611
Product Catalog